PRODUCTS HOME ABOUT US NEWS & PRESS CONTACT US
  Solar Water Heater   |    Solar Module    |    Solar lighting   |    Wind Turbine    |    Electric Bicycle   |    Tool Box   |   
SOLAR HEATING
Non-pressure type Solar Water Heaters
  Thermosyphon Tubular Solar Water Heater
(color steel)
  Thermosyphon Tubular Solar Water Heater
(stainless steel
)
 
Pressure type
Solar Water Heaters
  All-glass Evacuated Tubular Solar Collector with Heat Pipe
 
 
 
 
 
Solar Tubes
  All-glass Evacuated Solar Collector Tube
  All-glass Evacuated Solar Collector Tube with Heat Pipe
 
 
Solar Parts
  Pressurized Tank 
  Workstation
 
 
 
 
 

1
1SOLAR HEATING
1
1SOLAR MODULE
1
1SOLAR LIGHTTING
1
1WIND TURBINE
1
2ELECTRIC BICYCLE
TOOL BOX

Home > Products > Solar > Solar Water Heaters >
SF-A
d347_web_md.jpg
Larger View
System Controller
System Controller For Solar Heating Systems
1)Power supply: AC 220V ±10%, power consumption: < 5W.
2)Accuracy of tested temperature: ±2 °C
3)Range of temperature to be tested: 0~99 °C
4)Power of controllable cycle pump: < 800W
5)Creepage protection of electric heater: 10mA, 0.3S
6)Power of electric heater: <= 1500W
User Guide
download
System Controller
Go
Features | Specifications | Size | Accessories |

Description


Place of Origin China Model Number System Controller
Price Terms FOB, CIF Brand Name Sunline& OEM
Payment Terms T/T, L/C Minimum Order 1 sets
Supply Ability 2,500sets/month Delivery Time 7 days

Main functions


Main technical specifications
1)Power supply: AC 220V ±10%, power consumption: < 5W.
2)Accuracy of tested temperature: ±2 °C
3)Range of temperature to be tested: 0~99 °C
4)Power of controllable cycle pump: < 800W
5)Creepage protection of electric heater: 10mA, 0.3S
6)Power of electric heater: <= 1500W


Operation of button


1. ON/OFF button
After turn on, it means the machine is started automatically. The control will display water temperature of water tank, Beijing time. Each functional button is effect. Various work parameters can be set. Press this button after start, stop work and enter into the state of stopping machine. It will display temperature of water tank and Beijing time only. After stop, if press this button, start this machine again.

2. Button of clock
Press this button, flash indication at clock region. Use subscriptive time plus and minus button to adjust correct Beijing time.

3. Subscriptive time button regularly
3.1 Press this button, flash indication at clock region. Use subscriptive time plus and minus button to adjust starting time of electric heating.
3.2 Press this button again, flash indication at clock region. Use subscriptive time plus and minus button to adjust stopping time of electric heating.
3.3 The system has memory function. After the set is finished, it will start electric heating automatically when the set time is reached.
3.4 The heating time of system memory:17:00~22:00 everyday.

4. Button of heat compulsory
4.1 Press this button, start electric heating and relative icon lights;

5. Plus/Minus button for temperature of water tank
This button is used for setting temperature of water tank.

6. Setting button of cycle pump temperature
Press this button, set temperature value for starting cycle pump. Press this button again, the set temperature will increase 1 ℃ each time, it will be from 2℃ to 15℃. 6 seconds late, microcomputer will affirm your set value and convert it automatically and display temperature of water tank.

7. Setting button for stopping temperature of cycle pump
Press this button, set temperature value for stopping cycle pump. Press this button again, the set temperature will increase 1℃ each time, it will be from 0℃ to 10℃. 6 seconds late, microcomputer will affirm your set value and convert it automatically and display temperature of water tank.

8. ON/OFF button of pump forcibly
8.1 Press this button, start cycle pump and relative icon lights;
8.2 Press this button again, stop cycle pump.

9. Display conversion button
Press this button. It will convert to display the temperature of water tank and heat collector. If does not operate within 5 seconds, it will convert to display temperature of water tank.

10. Affirm/Cancel button
It is used for the temperature set of cycle pump and stopping temperature set of cycle pump.

11. Reset button
When system appears abnormal condition, press this button, it will restore the set of delivery.


Display table of code


Number of code

Phenomenon of code

Display of code

ERROR 1

Temperature sensor of heat collector takes place trouble.

E1

ERROR 2

Temperature sensor of water tank takes place trouble.

E2

ERROR 3

Cycle pump takes place trouble.

E3

ERROR 4

Protection of cycle pump at high temperature

E4

ERROR 6

Protection of preventing from freezing

E6

ERROR 7

Protection of preventing from freezing

E7


Explanation of installation
The controller must be installed by personnel who passed regular training
The controller and display panel should be installed at reasonable position where is far away from bathtub and sprayer.
Power supply must be 250V, 10A and have three-end socket which is grounded reliably.
Guarantee of repair replacement and refund of substandard products
Within one year, if not damaged artificially the product carries out three guarantees, i.e. guarantees of repair replacement and refund of substandard products and maintain all the time.


Installation Drawing of the System


Larger View
 
Contact Us | About Us | Site Map
Copyright © 2005-2012 Sunline international All rights eserved. 
Sunline international
E-mail: info@sunline.com.cn